Cyclic Tests of Cantilever CMU Wall Specimen C2 at WSU
|
DOI:10.4231/D33X83K65
Experiment Type: Large Scale
Description: Wall Specimen C2 had a height-to-length aspect ratio of 2.0, No. 4 vertical reinforcement spaced 8-in. on center with a splice length of 16 in. at the base of the wall, No. 4 horizontal reinforcement spaced 8-in. on center, and an axial load of 48 kips.
Dates: January 10, 2012 - May 20, 2012
Facility: Washington State University, WA, United States
Equipment:
Specimen Type: Wall Specimen C2 at WSU Material
Material: Material Properties Material Properties (view)
Sensors: WSU-C2 Sensor Location
Drawings:
Data:
Trial ( ? ) Repetition ( ? ) Interactive ( ? ) UnprocessedConvertedCorrectedDerived
Loading Trial-1..
Documentation:
Related Documents:
Analysis:
No files available
Images:
Tags (keywords):
  1. quasi-static
  2. Shear Wall
  3. seismic performance
  4. reinforced masonry
Cite this work:
Farhad Ahmadi (2013). "Cyclic Tests of Cantilever CMU Wall Specimen C2 at WSU", Network for Earthquake Engineering Simulation (distributor), Dataset, DOI:10.4231/D33X83K65