Support

Support Options

Submit a Support Ticket

 

NEES Project Warehouse

Seismic Design of Reinforced Masonry Shear-wall Structures
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-26: Cyclic Tests of Cantilever CMU Wall Specimen 2A at WSU
Dates: March 10, 2011 - March 10, 2012
Description: Specimen 2A had an aspect ratio of 2.0, No. 4 flexural reinforcement spaced 8 in. on center with no splice at the wall base, No. 4 shear reinforcement spaced 8 in. on center, and an axial load of 95 kips
Facility: Washington State University, WA, United States


  Experiment-27: Cyclic Tests of Cantilever CMU Wall Specimen 2B at WSU
Dates: March 10, 2011 - March 10, 2012
Description: Specimen 2B had an aspect ratio of 2.0, No. 4 flexural reinforcement spaced 8 in. on center with a 16-in. long splice at the wall base, No. 4 shear reinforcement spaced 8 in. on center, and an axial load of 95 kips.
Facility: Washington State University, WA, United States


  Experiment-28: Cyclic Tests of Cantilever CMU Wall Specimen 3 at WSU
Dates: March 10, 2011 - March 10, 2012
Description: Specimen 3 had an aspect ratio of 1.0, No. 4 flexural reinforcement spaced 8 in. on center with a 16-in. long splice at the wall base, No. 4 shear reinforcement spaced 24 in. on center, and zero axial load.
Facility: Washington State University, WA, United States


  Experiment-29: Cyclic Tests of Cantilever CMU Wall Specimen 4 at WSU
Dates: March 10, 2011 - March 10, 2012
Description: Specimen 4 had an aspect ratio of 1.0, No. 4 flexural reinforcement spaced 8 in. on center with a 16-in. long splice at the wall base, No. 4 shear reinforcement spaced 8 in. on center, and an axial load of 86 kips.
Facility: Washington State University, WA, United States


  Experiment-30: Cyclic Tests of Cantilever CMU Wall Specimen 5 at WSU
Dates: March 10, 2011 - March 10, 2012
Description: Specimen 5 had an aspect ratio of 0.78, No. 4 flexural reinforcement spaced 8 in. on center with a 16-in. long splice at the wall base, No. 4 shear reinforcement spaced 8 in. on center, and zero axial load.
Facility: Washington State University, WA, United States


  Experiment-31: Cyclic Tests of Cantilever CMU Wall Specimen 6 at WSU
Dates: March 10, 2011 - March 10, 2012
Description: Specimen 6 had an aspect ratio of 0.78, No. 4 flexural reinforcement spaced 8 in. on center with a 16-in. long splice at the wall base, two No. 4 shear bars spaced 8 in. on center, and an axial load of 86 kips.
Facility: Washington State University, WA, United States


  Experiment-32: Cyclic Tests of Cantilever CMU Wall Specimen C1 at WSU
Dates: January 10, 2012 - May 20, 2012
Description: Wall Specimen C1 had a height-to-length aspect ratio of 2.0, No. 4 vertical reinforcement spaced 8-in. on center with a splice at the base of the wall, No. 4 horizontal reinforcement spaced 8-in. on center, and zero axial load. The length of the lap...
Facility: Washington State University, WA, United States


  Experiment-33: Cyclic Tests of Cantilever CMU Wall Specimen C2 at WSU
Dates: January 10, 2012 - May 20, 2012
Description: Wall Specimen C2 had a height-to-length aspect ratio of 2.0, No. 4 vertical reinforcement spaced 8-in. on center with a splice length of 16 in. at the base of the wall, No. 4 horizontal reinforcement spaced 8-in. on center, and an axial load of 48 kips...
Facility: Washington State University, WA, United States


  Experiment-34: Cyclic Tests of Cantilever CMU Wall Specimen C3 at WSU
Dates: January 10, 2012 - May 20, 2012
Description: Wall Specimen C3 had a height-to-length aspect ratio of 2.0, No. 7 vertical reinforcement spaced 16-in. on center with a splice length of 46 in. at the base of the wall, No. 4 horizontal reinforcement spaced 8-in. on center, and an axial load of 48 kips...
Facility: Washington State University, WA, United States


  Experiment-35: Cyclic Tests of Cantilever CMU Wall Specimen C4 at WSU
Dates: January 10, 2012 - May 20, 2012
Description: Wall Specimen C4 had a height-to-length aspect ratio of 0.78, No. 7 vertical reinforcement spaced 16-in. on center with a splice length of 46 in. at the base of the wall, two No. 4 horizontal reinforcement spaced 8-in. on center, and an axial load of...
Facility: Washington State University, WA, United States


  Experiment-36: Cyclic Tests of Cantilever CMU Wall Specimen C5 at WSU
Dates: February 10, 2012 - May 20, 2012
Description: Wall Specimen C5 had a height-to-length aspect ratio of 1.0, No. 7 vertical reinforcement spaced 16-in. on center with a splice length of 46 in. at the base of the wall, two No. 4 horizontal reinforcement spaced 8-in. on center, and an axial load of...
Facility: Washington State University, WA, United States


  Experiment-37: Cyclic Tests of Cantilever CMU Wall Specimen C6 at WSU
Dates: January 10, 2012 - May 20, 2012
Description: Wall Specimen C6 had a height-to-length aspect ratio of 2.0, No. 6 vertical reinforcement spaced 8-in. on center with no splice at the base of the wall, No. 4 horizontal reinforcement spaced 16-in. on center, and zero axial load.
Facility: Washington State University, WA, United States


  Experiment-38: Cyclic Tests of Cantilever CMU Wall Specimen C7 at WSU
Dates: February 10, 2012 - May 20, 2012
Description: Wall Specimen C7 had a height-to-length aspect ratio of 2.0, four No. 6 vertical reinforcement bars located in the two outermost cells (jamb reinforcement) and one No. 4 vertical reinforcement bar located at mid-length, two No. 3 horizontal reinforcement...
Facility: Washington State University, WA, United States


  Experiment-39: Cyclic Tests of Cantilever CMU Wall Specimen C8 at WSU
Dates: February 10, 2012 - May 20, 2012
Description: Wall Specimen C8 had a height-to-length aspect ratio of 2.0, four No. 6 vertical reinforcement bars located in the two outermost cells (jamb reinforcement) and one No. 4 vertical reinforcement bar located at mid-length, two No. 3 horizontal reinforcement...
Facility: Washington State University, WA, United States


  Experiment-40: Cyclic Tests of Cantilever CMU Wall Specimen BE-1 with Boundary Elements, at WSU
Dates: March 30, 2012 - August 30, 2012
Description: Specimen BE-1 had a wall aspect ratio of 2.0, four confined No. 6 vertical reinforcing bars located at the ends of the wall and one No. 4 vertical bar located at mid-length, two No. 3 horizontal bars spaced at 8 in. on center over the height of the wall...
Facility: Washington State University, WA, United States


  Experiment-41: Cyclic Tests of Cantilever CMU Wall Specimen BE-2 with Boundary Elements, at WSU
Dates: March 10, 2012 - August 30, 2012
Description: Specimen BE-2 had an aspect ratio of 2.0, four confined No. 6 vertical reinforcing bars located at the ends of the wall and one No. 4 vertical bar located at mid-length, two No. 3 horizontal bars spaced 8 in. on center, and a 66 kip axial load. Confinement...
Facility: Washington State University, WA, United States


  Experiment-42: Cyclic Tests of Cantilever CMU Wall Specimen BE-3 with Boundary Elements, at WSU
Dates: April 19, 2012 - August 30, 2012
Description: Specimen BE-3, with wall returns at each end, had an aspect ratio of 2.0, four confined No. 6 and four confined No. 3 vertical reinforcing bars located at the ends of the wall, one No. 4 vertical bar located at mid-length, two No. 3 horizontal bars spaced...
Facility: Washington State University, WA, United States


  Experiment-43: Cyclic Tests of Cantilever CMU Wall Specimen BE-4 with Boundary Elements, at WSU
Dates: April 26, 2012 - August 30, 2012
Description: Specimen BE-4, with wall returns at each end, had an aspect ratio of 2.0, four confined No. 6 and four confined No. 3 vertical reinforcing bars located at the ends of the wall, one No. 4 vertical bar located at mid-length, two No. 3 horizontal bars spaced...
Facility: Washington State University, WA, United States
Display Num Results 26 - 43 of 43