NEES.org will be intermittently unavailable Saturday, January 3, for scheduled maintenance. All tool sessions will be expired. We apologize for any inconvenience that may occur.

Support

Support Options

Submit a Support Ticket

 

NEES Project Warehouse

Seismic Performance of Five Reinforced Concrete Buildings with Structural Walls at Tohoku University during the Tohoku, Japan, Earthquake of 2011
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-1: Data Collection of the Seismic Performance of the Building of the Department of Civil Engineering and Architecture at Tohoku University during the Tohoku, Japan, Earthquake of 2011
Dates: October 28, 2011 - March 31, 2012
Description: The Building of the Department of Civil Engineering and Architecture at Tohoku University is a nine-story, reinforced concrete building that was built in 1969. It has a two-story base and a seven-story tower. The total floor area is approximately 9203...
Facility:
Research Building of Civil Engineering and Architecture (facing West)

 Launch

2 Interactive Files
view data


  Experiment-2: Data Collection of the Seismic Performance of the Building of the Department of Electrical Engineering at Tohoku University during the Tohoku, Japan, Earthquake of 2011
Dates: October 28, 2011 - October 31, 2011
Description: The Research Building of Electrical Engineering is an eight-story reinforced concrete building built in 1966. The total floor area is approximately 9828 m2. The building has a height of 36.8 m, and the typical floor plan dimensions are 62 m by 20 m....
Facility:


  Experiment-3: Data Collection of the Seismic Performance of the Building of the Department of Materials Engineering at Tohoku University during the Tohoku, Japan, Earthquake of 2011
Dates: October 28, 2011 - October 31, 2011
Description: The Research Building of Materials Engineering was built in 1968. This structure is a six-story reinforced concrete building. The building has a total floor area of 7663 m2, a footprint of 56 m by 18.8 m, and a height of 29.5 m. The structural system...
Facility:


  Experiment-4: Data Collection of the Seismic Performance of the North and South Lecture Buildings of the Department of Electrical Engineering at Tohoku University during the Tohoku, Japan, Earthquake of 2011
Dates: October 28, 2011 - October 31, 2011
Description: The Electrical Engineering North and South Lecture Buildings were built in 1966 at the same time as the Electrical Engineering Research Building. These structures are two two-story reinforced concrete buildings. Each of these structures has an area of...
Facility: