Support

Support Options

Submit a Support Ticket

 

NEES Project Warehouse

Development of a Performance-Based Seismic Design Philosophy for Mid-Rise Woodframe Construction
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-1: Phase 1 - Wood only
Dates: June 05, 2006 - June 09, 2006
Description: Seismic tests of wood-only structure (no gypsum and stucco)
Facility: State University of New York at Buffalo, NY, United States
The Test Structure After Roof Completion

 Launch

9 Interactive Files
view data


  Experiment-2: Phase 2 - Wood with viscous dampers
Dates: June 26, 2006 - June 30, 2006
Description: Phase 1 structure (wood only) with pre-fabricated viscous damper walls in X direction (longitudinal). Damper walls were designed by RPI team.
Facility: State University of New York at Buffalo, NY, United States
The Side Wall Dampers which are unique to Phase 2

 Launch

7 Interactive Files
view data


  Experiment-3: Phase 3 - Wood with gypsum on structural walls only
Dates: July 12, 2006 - August 04, 2006
Description: Phase 1 structure (wood only) with gypsum on structural walls only
Facility: State University of New York at Buffalo, NY, United States
The Drywall which was installed for Phase 3 Tests

 Launch

4 Interactive Files
view data


  Experiment-4: Phase 4 - Wood with gypsum everywhere
Dates: August 28, 2006 - September 01, 2006
Description: Phase 1 structure (wood only) with gypsum everywhere (structural walls, partition walls, ceilings). Drywalls were installed by SUNY-ECC staffs and students.
Facility: State University of New York at Buffalo, NY, United States
Phase 4 Structure

 Launch

4 Interactive Files
view data


  Experiment-5: Phase 5 - Completed structure (wood+gypsum+stucco)
Dates: November 06, 2006 - November 15, 2006
Description: Wood-only structure with gypsum everywhere (structural walls, partition walls, ceilings) and stucco.
Facility: State University of New York at Buffalo, NY, United States
Test Structure after Stucco Finish

 Launch

10 Interactive Files
view data
Start Prev 1 Next End