Support

Support Options

Submit a Support Ticket

 

NEES Project Warehouse

Hybrid Masonry Seismic Structural Systems
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-1: Single Steel Connector Plate Testing.
Dates: July 01, 2010 - June 30, 2011
Description: Testing at the University of Hawaii @ Manoa as part of Project Task 2: Connector Development. This experiment is the first round of testing the prototypical connector plates. These connectors will be used to transfer the load between the steel framing...
Facility: University of Hawaii at Manoa, HI, United States
Test Setup for Experiment 1 - Single Connector Plate Testing

 Launch

19 Interactive Files
view data


  Experiment-2: Masonry Bolt Pushout Testing
Dates: November 04, 2010 - November 08, 2011
Description: Testing at the University of Hawaii @ Manoa as part of Project Task 2: Connector Development. This experiment was to determine the characteristics of the bolt-pushout failure mode for Type 1 hybrid masonry systems. By obtaining the ultimate strength...
Facility: University of Hawaii at Manoa, HI, United States
Hybrid Masonry push-out test of through bolt

 Launch

16 Interactive Files
view data


  Experiment-3: Double Steel Connector Plate Testing
Dates: July 22, 2010 - June 30, 2012
Description: Testing at the University of Hawaii @ Manoa as part of Project Task 2: Connector Development. This experiment is the second round of testing the prototypical connector plates. These tests focus on connectors that attach to the above I-beam via plates...
Facility: University of Hawaii at Manoa, HI, United States
Test Setup for Double Connector Plate Testing

 Launch

12 Interactive Files
view data


  Experiment-5: Preliminary Masonry Prism Compression Tests
Dates: June 01, 2011 - June 01, 2011
Description: Concrete masonry prism testing at the University of Illinois at Urbana-Champaign: both grouted and ungrouted prism compressive strength were tested using the 600 Kip MTS uniaxial servo-controlled hydraulic frame. Compressive strength was measured with...
Facility: University of Illinois at Urbana-Champaign, IL, United States
Enter experiment photo caption

 Launch

6 Interactive Files
view data


  Experiment-6: Small Scale Testing of Hybrid Masonry
Dates: January 15, 2010 - September 06, 2011
Description: Small scale testing of the hybrid masonry system at the University of Illinois at Urbana-Champaign's MUST-SIM facility. This testing was conducted to validate the control software as well as discover any issues with the specimen design and loading pattern...
Facility: University of Illinois at Urbana-Champaign, IL, United States
Enter experiment photo caption

 Launch

10 Interactive Files
view data


  Experiment-7: Large Scale Testing of Hybrid Masonry
Dates: October 01, 2010 - September 30, 2013
Description: A large-scale specimen underwent testing at the University of Illinois at Urbana-Champaign in the Multi-Axial Full-Scale Sub-Structured Testing and Simulation (MUST-SIM) facility, which is part of the National Science Foundation (NSF) George E. Brown...
Facility: University of Illinois at Urbana-Champaign, IL, United States


  Experiment-8: Steel Connector Plate Wall Testing
Dates: November 04, 2011 - April 26, 2012
Description: Testing at the University of Hawaii @ Manoa as part of Project Task 2: Connector Development. This experiment is the third round of testing Type I hybrid masonry connector plates. Multiple pairs of previously tested tapered fuse connectors were slip-...
Facility: University of Hawaii at Manoa, HI, United States
Hybrid Masonry Type I wall test

 Launch

10 Interactive Files
view data


  Experiment-9: CMU Wall Through-bolt Pushout
Dates: January 15, 2012 - November 15, 2012
Description: Testing at the University of Hawaii @ Manoa as part of Project Task 2: Connector Development. This experiment is the second round of testing to establish the masonry capacity at through-bolt point loading. Steel link plates were slip-critically bolted...
Facility: University of Hawaii at Manoa, HI, United States
Start Prev 1 Next End
Display Num Results 1 - 8 of 8