NSF RAPID: Post-Earthquake Monitoring of Buildings in Chile Using NEES@UCLA Resources: NSF RAPID CMMI-1040574
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-1: Ambient Vibration Testing of 10 Story Office Building (Building 2)
Dates: March 24, 2010 - March 28, 2010
Description: Building 2 is a 10 story reinforced concrete building with six levels of subterranean parking. The building was under interior construction at the time of instrumentation and provided several unoccupied floors for easy access and installation. The structural...
Facility: University of California, Los Angeles, CA, United States
Building 2 - 10 story office building

 Launch

1 Interactive Files
view data


  Experiment-2: Ambient Vibration Testing of 25 Story Office Building (Building 1)
Dates: March 17, 2010 - March 28, 2010
Description: Building 1 is a 25 story office building whose lateral force resisting system consists of two inner-core shear wall elevator shafts complemented by an external beam-column frame system. The office building has three subterranean stories of underground...
Facility: University of California, Los Angeles, CA, United States
23 story office building - ambient vibration testing

 Launch

1 Interactive Files
view data


  Experiment-3: Ambient Vibration Testing of 10 Story Residential Building (Building 3)
Dates: March 17, 2010 - May 06, 2010
Description: This building was located in a newly developed residential district of Santiago in the north-east of the city and represents a 10-story reinforced concrete shear wall building with one level of underground parking. At the time of deployment (March 2010...
Facility: University of California, Los Angeles, CA, United States


  Experiment-4: Ambient Vibration Testing of a 5 Story Office Building (Building 4)
Dates: May 05, 2010 - May 09, 2010
Description: Building 4 was a 5 story moment frame office building which was under interior construction at the time of instrumentation. Large amounts of ambient vibrations were measured but no aftershocks were captured in Building 4 during the instrumented period...
Facility: University of California, Los Angeles, CA, United States
Start Prev 1 Next End