Performance Evaluation of Semi-rigid Steel Frames Using Hybrid Simulation
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-1: Beam Column Connection Cyclic Test 70% Web Angles
Dates: April 24, 2010 to Present
Description: Due to some technical problems associated with one of the LBCBs, cyclic testing of the 70% Mpbeam was not conducted.
Facility: University of Illinois at Urbana-Champaign, IL, United States


  HybridSimulation-1: Beam Column Connection Hybrid Simulation 30% Web Angles
Dates: October 16, 2009 - October 16, 2009
Description: This experiment is a hybrid simulation of a partial-strength semi-rigid frame with connection capacity that is 30% of the plastic moment capacity of the beam. The simulation utilized the large-scale Multi-Axial Full-scale Sub-Structured Testing and simulation...
Facility: University of Illinois at Urbana-Champaign, IL, United States


  HybridSimulation-2: Beam Column Connection Hybrid Simulation 70% Web Angles
Dates: August 04, 2010 - August 04, 2010
Description: This experiment is a hybrid simulation of a partial-strength semi-rigid frame with connection capacity that is 70% of the plastic moment capacity of the beam. The simulation utilized the large-scale Multi-Axial Full-scale Sub-Structured Testing and simulation...
Facility: University of Illinois at Urbana-Champaign, IL, United States


  HybridSimulation-3: Beam Column Connection Hybrid Simulation 50% Web Angles
Dates: December 09, 2009 - December 09, 2009
Description: This experiment is a hybrid simulation of a partial-strength semi-rigid frame with connection capacity that is 50% of the plastic moment capacity of the beam. The simulation utilized the large-scale Multi-Axial Full-scale Sub-Structured Testing and simulation...
Facility: University of Illinois at Urbana-Champaign, IL, United States


  Experiment-2: Beam Column Connection Cyclic Test 30% Web Angles
Dates: October 19, 2009 - October 19, 2009
Description: Cyclic testing completed for a period of 15 seconds of an earthquake. Cyclic tests are conducted to evaluate the post-earthquake behavior of the connection and its residual characteristics including stiffness, strength, and ductility. Cyclic tests are...
Facility: University of Illinois at Urbana-Champaign, IL, United States


  Experiment-3: Beam Column Connection Cyclic Test 50% Web Angles
Dates: December 08, 2009 - December 08, 2009
Description: Cyclic testing completed for a period of 15 seconds of an earthquake. Cyclic tests are conducted to evaluate the post-earthquake behavior of the connection and its residual characteristics including stiffness, strength, and ductility. Cyclic tests are...
Facility: University of Illinois at Urbana-Champaign, IL, United States
Start Prev 1 Next End
Display Num Results 1 - 6 of 6