Venue Stampede is now available for Batchsubmit.

Support

Support Options

Submit a Support Ticket

 

NEES Project Warehouse

Assessment of Punching Shear Vulnerability of Slab-Column Connections with Shear Stud Reinforcement
No reviews have been created for this project. Review This Project

To compare experiments, please select at most four experiments from the experiment list below.

Sort By:   

  Experiment-1: Slab-Column Connection with Orthogonal Arrangement of Twelve SSR Assemblies with Stud Spacing of 0.5*d
Dates: December 08, 2010 - December 10, 2010
Description: 1-1/2 Story Flat Plate Slab/Column Sub-assembly with Headed Shear-Stud Reinforcement. Three shear stud rail assemblies were placed orthogonal to each face of the column (12 total). The spacing of shear studs on each assembly was equal to d/2.
Facility: University of Minnesota-Twin Cities, MN, United States


  Experiment-2: Slab-Column Connection with Orthogonal Arrangement of Twelve SSR Assemblies with Stud Spacing of 0.75*d
Dates: March 03, 2011 - March 03, 2011
Description: 1-1/2 Story Flat Plate Slab/Column Sub-assembly with Headed Shear-Stud Reinforcement. Three shear stud rail assemblies were placed orthogonal to each face of the column (12 total). The spacing of shear studs on each assembly was equal to 3d/2.
Facility: University of Minnesota-Twin Cities, MN, United States


  Experiment-3: Slab-Column Connection with Twelve Radial Arrangement of SSR Assemblies with Stud Spacing of 0.5*d
Dates: July 19, 2011 - July 21, 2011
Description: 1-1/2 Story Flat Plate Slab/Column Sub-assembly with Headed Shear-Stud Reinforcement. Two shear stud rail assemblies were placed orthogonal to each face of the column, and one was placed at each column corner at a 45-degree angle to each face (12 were...
Facility: University of Minnesota-Twin Cities, MN, United States


  Experiment-4: Slab-Column Connection with RadialArrangement of Twenty SSR Assemblies with Stud Spacing of 0.5*d
Dates: December 09, 2011 - December 14, 2011
Description: 1-1/2 Story Flat Plate Slab/Column Sub-assembly with Headed Shear-Stud Reinforcement. Four shear stud rail assemblies were placed orthogonal to each face of the column, and one was placed at each column corner at a 45-degree angle to each face (20 were...
Facility: University of Minnesota-Twin Cities, MN, United States
Start Prev 1 Next End
Display Num Results 1 - 4 of 4