Hybrid Masonry Seismic Structural Systems
Curation progress:

Experiment contains sensor data, metadata, and required documentation including the experiment report.

Complete - 12/03/2013

What's this?

The curation dashboard shows your progress as you add required elements to your project or experiment.

Experiment-3: Double Steel Connector Plate Testing
Experiment Type: Other
Description: Testing at the University of Hawaii @ Manoa as part of Project Task 2: Connector Development. This experiment is the second round of testing the prototypical connector plates. These tests focus on connectors that attach to the above I-beam via plates welded flange-flange on either side of the beam (with the exception of the bent-plate test in Trial 6). In each test, two connectors, one on each side of the beam, are loaded simultaneously, thus the data reflects the combined performance of the connector plates.
Dates: July 22, 2010 - June 30, 2012
Facility: University of Hawaii at Manoa, HI, United States
Specimen Type: Hybrid Masonry
Material: Component 1 Component 1 (view)
Sensors: Experiment 3 Sensor List
Trial ( ? ) Repetition ( ? ) Interactive ( ? ) UnprocessedConvertedCorrectedDerived
Loading Trial-1..
Loading Trial-2..
Loading Trial-3..
Loading Trial-4..
Loading Trial-5..
Loading Trial-6..
Related Documents:
No files available
Tags (keywords):
  1. Hybrid Masonry
  2. Ductile fuse connector
  3. cyclic testing
Cite this work:
Reef Ozaki-Train, Gaur Johnson, Ian Robertson (2013). "Double Steel Connector Plate Testing", Network for Earthquake Engineering Simulation (distributor), Dataset, DOI:10.4231/D3V40K009