Support Options

Submit a Support Ticket


NEES Project Warehouse

RAPID: Mapping of Earthquake Damage in Precast Buildings in Christchurch, New Zealand
Curation progress:

Experiment contains unprocessed data, required metadata and documentation, including the experimental report.

Complete - 03/04/2013

What's this?

The curation dashboard shows your progress as you add required elements to your project or experiment.

Experiment-1: Field monitoring of a 9-story, precast concrete, moment resisting frame building
Experiment Type: Field
Description: Ambient vibration measurements and triggered aftershock recordings were taken on a nine story hotel. The hotel was a precast concrete structure with a moment resisting frame for lateral load resistance. The structure was damaged in the Christchurch earthquake and subsequent aftershocks. During field measurements, the building was being inspected for damage with partition removal and content storage as the primary activities underway.
The structure's latitude and longitude are -43.53190 and 172.635515, respectively.
Dates: July 14, 2011 - September 06, 2011
Facility: University of California, Los Angeles, CA, United States
Equipment: View Details
Specimen Type: 9-story hotel
Material: Prestressed concrete beam Prestressed concrete beam (view)
Cast-in-place column Cast-in-place column (view)
Floors Floors (view)
Sensors: Trial 7
Trial 8
Trial 9
Trial 10
Trial 11
Trial 12
Trial 13
Trial 14
Trial 15
Trial 16
Trial 17
Trial 18
Trial 20
Trial 1
Trial ( ? ) Repetition ( ? ) Interactive ( ? ) UnprocessedConvertedCorrectedDerived
Loading Trial-1..
Loading Trial-7..
Loading Trial-8..
Loading Trial-9..
Loading Trial-10..
Loading Trial-11..
Loading Trial-12..
Loading Trial-13..
Loading Trial-14..
Loading Trial-15..
Loading Trial-16..
Loading Trial-17..
Loading Trial-18..
Loading Trial-20..
Related Documents:
No files available
Tags (keywords):
  1. Christchurch Earthquake
  2. precast concrete
  3. System Identification
Cite this work:
Jose Restrepo, Robert Fleischman, Matthew Schoettler (2013). "Field monitoring of a 9-story, precast concrete, moment resisting frame building", Network for Earthquake Engineering Simulation (distributor), Dataset, DOI:10.4231/D3S46H587